Commercial grade aluminum extruded product in minimum 6063-T6/T54 alloy with polyamide thermal break. Assembled by rolling and crimping with a minimum 400 kg shear test. Generally used for access to balconies in large buildings.

This product is designed as a pressure-balanced rain screen with a pressure equalization chamber to prevent water infiltration.

All seals are made of SILICONE or EPDM depending on their location and function in the system.

Insulated Glass Unit (IGU) options: 25mm (1”), 32mm (1 ¼”) and 38mm (1 ½”).

This product cannot include insect screens or Juliette-type railings because of its exterior opening.

This product is equipped with :
  • 1 OSIRIDE single lever handle from Fapim #0640B05;
  • 1 STAC bi-directional mechanism #0507248;
  • 2 Adjustable rod ends from Fapim #1589;
  • 3 MONZA aluminum axial hinges from Fapim #5671, multi-point locking; Number of strike plates varies according to product dimensions;
  • 2 STAC retaining strike #0507047;
  • 1 Southco black ABS pull handle #B8-63 and Ferco opening limiter with brake;
Also available with exterior access, 9000 Series
  • 1 HORUS double crutch from Fapim #2051i;
  • 3 MONZA aluminum axial hinges from Fapim #5671;
  • 1 Fapim multipoint lock with EGO
  • bolt #2523C; Number of strike plates varies according to product dimensions;
  • 2 STAC retaining strike #0507047;
  • 1 European-style solid brass lock cylinder with key and knob 70mm/30mm;
  • 2 Fapim European cylinder entrance plates #2100B;
  • 1 Ferco 90o opening limiter compass.

Technical performance

Primary product designation :

CW – PG70 – type C

Air infiltration/exfiltration :

A3: Maximum 0,25 l/s-m2 @ 75 Pa

In accordance with AAMA/WDMA/CSA 101/i.S.2/A-440-11 (9.3.2), A-440S1-17, ASTM-E283-04

Water resistance test :

No water infiltration at 720 Pa

In accordance with AAMA/WDMA/CSA 101/i.S.2/A-440-11 (9.3.3), ASTM-E547, ASTM-E331

Uniform load deflexion :

Deflexion limited to L/175

Achieved test level of the product at 3360 Pa (70 lbs/ft2) on a 1200 x 2400 mm (47 x 94 in) specimen

In accordance with AAMA/WDMA/CSA 101/i.S.2/A-440-11 (9.3.4), ASTM-E330-02

Forced entry resistance :

No opening that allows entry under a load of 135 kg (300lbs)

In accordance with AAMA/WDMA/CSA 101/i.S.2/A-440-11 (9.3.5), ASTM-F588-07

Cycle test :

No damage or permanent breakage after 250,000 operating cycles

In accordance with AAMA/WDMA/CSA 101/i.S.2/A-440-11 (9.3.5), ASTM-F588-07